AI summary by TwinMind

12. Ion Implantation and Annealing - Analytic Models and Monte Carlo

MIT OpenCourseWare

1h 16m 37s

Course Administration

  • Schedule change: Supreme 4 process simulator lecture moved later
    • Need to cover Transit Enhanced Diffusion (TED) first
    • Today covering ion implantation instead (4 lectures total)
  • Homework #4 delayed due to Red Sox game
  • Handout #20 distributed: Term project topics and requirements
    • ~15 potential topics listed (not exhaustive)
    • Topics include: dopant diffusion in SiGe, laser annealing, selective epitaxial growth
    • Requires instructor approval
    • Choice between 20-page written report or 15-17 minute oral presentation
    • Must research multiple papers, not just regurgitate one source
    • Oral presentations require handouts for class

Ion Implantation Introduction

  • Chapter 8 coverage over next 4 lectures
  • Only semiconductor process modelable from first principles
    • Based on fundamental physics vs empirical models
    • Fewer free parameters than other processes
  • Dominant method for introducing dopants despite lattice damage
  • Replaced traditional predeposition/drive-in methods

Historical Context and VT Control

  • Introduced to manufacturing late 1970s as enabling technology
  • Primary driver: accurate threshold voltage (VT) control in MOSFETs
  • VT equation includes ion implant term: Q×φ/Cox
    • φ = implant dose (atoms/cm²)
    • Precise dose control enables precise VT adjustment
  • Traditional predeposition method limitations:
    • Poor dose control (temperature/time sensitive)
    • 1 second at 1000°C gives 10¹⁴ atoms/cm² (too high for VT adjust)
    • Ion implant can achieve 10¹² atoms/cm² with excellent control

Dose Control Mechanism

  • Dose = (1/Area) × ∫(I/q)dt
    • I = beam current (measurable with ammeter)
    • q = electronic charge
    • Integration over time provides precise charge counting
  • Example calculation: 0.1 μA beam, 20×20 cm² area
    • Dose rate = 1.6×10⁹ atoms/cm²/sec
    • Excellent dynamic range (0.01 μA to mA beam currents)

Ion Implanter Design

  • Vacuum system with ion source and mass analyzer
  • Ion source: ionizes species (e.g., BF₂ gas → B⁺, F⁻, BF₂⁺)
  • Extraction voltage (0-30 kV) sets initial ion energy
  • E×B filter for mass selection
    • Centrifugal force = magnetic force (mv²/r = qvB)
    • Only desired mass passes through resolving slit
  • High voltage accelerator (50-200 kV) for final energy
  • X-Y scan plates for beam rastering across wafer
  • Current integrator for dose monitoring

Ion Distribution Physics

  • Random collision process with silicon atoms
  • Two energy loss mechanisms:
    • Nuclear collisions (billiard ball-like)
    • Electronic drag forces
  • Key parameters:
    • Total range: sum of all path segments
    • Projected range (Rp): depth projection (more important)
  • Statistical process creates distribution of final positions

Profile Characteristics by Ion Mass

  • Light ions (Boron): travel deeper, broader distributions
    • At 200 keV: Rp ≈ 0.55 μm, very broad profile
  • Heavy ions (Antimony): shallow, narrow distributions
    • At 200 keV: much shallower than Boron, tight distribution
  • Intermediate ions (Phosphorus, Arsenic): between extremes

Gaussian Approximation

  • First-order model: N(x) = Npeak × exp[-(x-Rp)²/(2ΔRp²)]
  • Two parameters: Rp (projected range), ΔRp (standard deviation)
  • Integrated dose Q = √(2π) × ΔRp × Npeak
  • Works well for heavy ions, less accurate for light ions
  • Tabulated values available in textbooks and literature

Lateral Distribution and Masking

  • 3D ion distribution: elongated ellipse in beam direction
  • Lateral straggle: ΔRp⊥ (perpendicular to beam)
  • Point response function approach for modeling
  • Mask edge effects critical for device dimensions
    • Lateral straggle under gate determines channel length
    • Important for short channel effects

Masking Calculations

  • Mask thickness requirement: Xm = Rp* + M×ΔRp*
    • * denotes parameters in mask material
    • M typically ~5 standard deviations
  • Penetrating dose: complementary error function
  • Tilted implants create shadowing effects
    • Often require symmetric tilts for device uniformity

Profile Evolution During Annealing

  • Simple case: Gaussian preserved during diffusion
  • Final standard deviation: √(ΔRp² + 4Dt)
  • Peak concentration decreases as profile broadens
  • More complex behavior in real systems due to TED

Advanced Profile Modeling

  • Real profiles show skewness (non-Gaussian behavior)
  • Light ions: skewed toward surface (backscattering)
  • Heavy ions: skewed deeper (forward momentum)

Pearson IV Distribution

  • Four-moment description: Rp, ΔRp, skewness (γ), kurtosis (β)
  • Differential equation solution for accurate profiles
  • Peak location: Rp + a (offset from Rp)
  • Skewness effects:
    • γ < 0 (Boron): peak deeper than Rp
    • γ > 0 (heavy ions): peak shallower than Rp
  • Tabulated parameters available for common dopants

Ion Channeling Effects

  • Single crystal silicon has open channels along crystal axes
  • Ions can travel much deeper via channeling
  • Critical angle (ψc): maximum misalignment for channeling
    • Boron <111>: ~3°, Arsenic <111>: ~4.4°
  • Dose-dependent effects:
    • Low dose: maintains crystal structure, deep channeling tails
    • High dose: amorphizes crystal, eliminates channeling

Channeling Control Methods

  • Controlled misalignment: 7° tilt + rotation
  • Amorphous overlayers (limited effectiveness)
  • Residual channeling still occurs at end-of-range
    • Critical angle increases as ions slow down
    • Creates exponential tail in profiles

Modeling Complexity Hierarchy

  • Gaussian (2 parameters): basic approximation
  • Pearson IV (4 parameters): accurate for amorphous
  • Pearson IV + exponential tail (6 parameters): includes channeling
  • Dual Pearson (9 parameters): complex channeling cases
  • Monte Carlo: most accurate but computationally intensive
  • Boltzmann Transport Equation (BTE): compromise approach

Monte Carlo Simulation

  • Follow individual ion trajectories from surface to rest
  • Statistical accuracy: error ∝ 1/√N
  • Requires ~10⁵ ions for 10% accuracy over 3 decades
  • Computationally expensive (hours to days)
  • Most accurate for complex geometries and channeling

Key Process Parameters

  • Beam energy: determines Rp and profile shape
  • Dose: total atoms implanted per unit area
  • Tilt angle: controls channeling
  • Rotation: randomizes crystal orientation
  • Masking materials: defines implant regions
  • Wafer temperature: affects damage accumulation
  • Dose rate: influences heating and damage kinetics

TwinMind

Get summaries like this for your own meetings

TwinMind takes notes in the background during meetings, lectures, and calls, then writes the summary for you.

Free plan to get started

No bot joins your calls

Phone, desktop & Chrome apps

Your next meeting, summarized like this

TwinMind listens in the background and turns meetings, lectures, and calls into searchable notes you can chat with. Start free.

Available on phone, desktop & Chrome

Your next meeting, summarized like this

TwinMind listens in the background and turns meetings, lectures, and calls into searchable notes you can chat with. Start free.

Available on phone, desktop & Chrome

Your next meeting, summarized like this

TwinMind listens in the background and turns meetings, lectures, and calls into searchable notes you can chat with. Start free.

Available on phone, desktop & Chrome