12. Ion Implantation and Annealing - Analytic Models and Monte Carlo

12. Ion Implantation and Annealing - Analytic Models and Monte Carlo

MIT OpenCourseWare

MIT OpenCourseWare

Course Administration

  • Schedule change: Supreme 4 process simulator lecture moved later
    • Need to cover Transit Enhanced Diffusion (TED) first
    • Today covering ion implantation instead (4 lectures total)
  • Homework #4 delayed due to Red Sox game
  • Handout #20 distributed: Term project topics and requirements
    • ~15 potential topics listed (not exhaustive)
    • Topics include: dopant diffusion in SiGe, laser annealing, selective epitaxial growth
    • Requires instructor approval
    • Choice between 20-page written report or 15-17 minute oral presentation
    • Must research multiple papers, not just regurgitate one source
    • Oral presentations require handouts for class

Ion Implantation Introduction

  • Chapter 8 coverage over next 4 lectures
  • Only semiconductor process modelable from first principles
    • Based on fundamental physics vs empirical models
    • Fewer free parameters than other processes
  • Dominant method for introducing dopants despite lattice damage
  • Replaced traditional predeposition/drive-in methods

Historical Context and VT Control

  • Introduced to manufacturing late 1970s as enabling technology
  • Primary driver: accurate threshold voltage (VT) control in MOSFETs
  • VT equation includes ion implant term: Q×φ/Cox
    • φ = implant dose (atoms/cm²)
    • Precise dose control enables precise VT adjustment
  • Traditional predeposition method limitations:
    • Poor dose control (temperature/time sensitive)
    • 1 second at 1000°C gives 10¹⁴ atoms/cm² (too high for VT adjust)
    • Ion implant can achieve 10¹² atoms/cm² with excellent control

Dose Control Mechanism

  • Dose = (1/Area) × ∫(I/q)dt
    • I = beam current (measurable with ammeter)
    • q = electronic charge
    • Integration over time provides precise charge counting
  • Example calculation: 0.1 μA beam, 20×20 cm² area
    • Dose rate = 1.6×10⁹ atoms/cm²/sec
    • Excellent dynamic range (0.01 μA to mA beam currents)

Ion Implanter Design

  • Vacuum system with ion source and mass analyzer
  • Ion source: ionizes species (e.g., BF₂ gas → B⁺, F⁻, BF₂⁺)
  • Extraction voltage (0-30 kV) sets initial ion energy
  • E×B filter for mass selection
    • Centrifugal force = magnetic force (mv²/r = qvB)
    • Only desired mass passes through resolving slit
  • High voltage accelerator (50-200 kV) for final energy
  • X-Y scan plates for beam rastering across wafer
  • Current integrator for dose monitoring

Ion Distribution Physics

  • Random collision process with silicon atoms
  • Two energy loss mechanisms:
    • Nuclear collisions (billiard ball-like)
    • Electronic drag forces
  • Key parameters:
    • Total range: sum of all path segments
    • Projected range (Rp): depth projection (more important)
  • Statistical process creates distribution of final positions

Profile Characteristics by Ion Mass

  • Light ions (Boron): travel deeper, broader distributions
    • At 200 keV: Rp ≈ 0.55 μm, very broad profile
  • Heavy ions (Antimony): shallow, narrow distributions
    • At 200 keV: much shallower than Boron, tight distribution
  • Intermediate ions (Phosphorus, Arsenic): between extremes

Gaussian Approximation

  • First-order model: N(x) = Npeak × exp[-(x-Rp)²/(2ΔRp²)]
  • Two parameters: Rp (projected range), ΔRp (standard deviation)
  • Integrated dose Q = √(2π) × ΔRp × Npeak
  • Works well for heavy ions, less accurate for light ions
  • Tabulated values available in textbooks and literature

Lateral Distribution and Masking

  • 3D ion distribution: elongated ellipse in beam direction
  • Lateral straggle: ΔRp⊥ (perpendicular to beam)
  • Point response function approach for modeling
  • Mask edge effects critical for device dimensions
    • Lateral straggle under gate determines channel length
    • Important for short channel effects

Masking Calculations

  • Mask thickness requirement: Xm = Rp* + M×ΔRp*
    • * denotes parameters in mask material
    • M typically ~5 standard deviations
  • Penetrating dose: complementary error function
  • Tilted implants create shadowing effects
    • Often require symmetric tilts for device uniformity

Profile Evolution During Annealing

  • Simple case: Gaussian preserved during diffusion
  • Final standard deviation: √(ΔRp² + 4Dt)
  • Peak concentration decreases as profile broadens
  • More complex behavior in real systems due to TED

Advanced Profile Modeling

  • Real profiles show skewness (non-Gaussian behavior)
  • Light ions: skewed toward surface (backscattering)
  • Heavy ions: skewed deeper (forward momentum)

Pearson IV Distribution

  • Four-moment description: Rp, ΔRp, skewness (γ), kurtosis (β)
  • Differential equation solution for accurate profiles
  • Peak location: Rp + a (offset from Rp)
  • Skewness effects:
    • γ < 0 (Boron): peak deeper than Rp
    • γ > 0 (heavy ions): peak shallower than Rp
  • Tabulated parameters available for common dopants

Ion Channeling Effects

  • Single crystal silicon has open channels along crystal axes
  • Ions can travel much deeper via channeling
  • Critical angle (ψc): maximum misalignment for channeling
    • Boron <111>: ~3°, Arsenic <111>: ~4.4°
  • Dose-dependent effects:
    • Low dose: maintains crystal structure, deep channeling tails
    • High dose: amorphizes crystal, eliminates channeling

Channeling Control Methods

  • Controlled misalignment: 7° tilt + rotation
  • Amorphous overlayers (limited effectiveness)
  • Residual channeling still occurs at end-of-range
    • Critical angle increases as ions slow down
    • Creates exponential tail in profiles

Modeling Complexity Hierarchy

  • Gaussian (2 parameters): basic approximation
  • Pearson IV (4 parameters): accurate for amorphous
  • Pearson IV + exponential tail (6 parameters): includes channeling
  • Dual Pearson (9 parameters): complex channeling cases
  • Monte Carlo: most accurate but computationally intensive
  • Boltzmann Transport Equation (BTE): compromise approach

Monte Carlo Simulation

  • Follow individual ion trajectories from surface to rest
  • Statistical accuracy: error ∝ 1/√N
  • Requires ~10⁵ ions for 10% accuracy over 3 decades
  • Computationally expensive (hours to days)
  • Most accurate for complex geometries and channeling

Key Process Parameters

  • Beam energy: determines Rp and profile shape
  • Dose: total atoms implanted per unit area
  • Tilt angle: controls channeling
  • Rotation: randomizes crystal orientation
  • Masking materials: defines implant regions
  • Wafer temperature: affects damage accumulation
  • Dose rate: influences heating and damage kinetics