12. Ion Implantation and Annealing - Analytic Models and Monte Carlo
12. Ion Implantation and Annealing - Analytic Models and Monte Carlo
MIT OpenCourseWare
MIT OpenCourseWare
Course Administration
- Schedule change: Supreme 4 process simulator lecture moved later
- Need to cover Transit Enhanced Diffusion (TED) first
- Today covering ion implantation instead (4 lectures total)
- Homework #4 delayed due to Red Sox game
- Handout #20 distributed: Term project topics and requirements
- ~15 potential topics listed (not exhaustive)
- Topics include: dopant diffusion in SiGe, laser annealing, selective epitaxial growth
- Requires instructor approval
- Choice between 20-page written report or 15-17 minute oral presentation
- Must research multiple papers, not just regurgitate one source
- Oral presentations require handouts for class
Ion Implantation Introduction
- Chapter 8 coverage over next 4 lectures
- Only semiconductor process modelable from first principles
- Based on fundamental physics vs empirical models
- Fewer free parameters than other processes
- Dominant method for introducing dopants despite lattice damage
- Replaced traditional predeposition/drive-in methods
Historical Context and VT Control
- Introduced to manufacturing late 1970s as enabling technology
- Primary driver: accurate threshold voltage (VT) control in MOSFETs
- VT equation includes ion implant term: Q×φ/Cox
- φ = implant dose (atoms/cm²)
- Precise dose control enables precise VT adjustment
- Traditional predeposition method limitations:
- Poor dose control (temperature/time sensitive)
- 1 second at 1000°C gives 10¹⁴ atoms/cm² (too high for VT adjust)
- Ion implant can achieve 10¹² atoms/cm² with excellent control
Dose Control Mechanism
- Dose = (1/Area) × ∫(I/q)dt
- I = beam current (measurable with ammeter)
- q = electronic charge
- Integration over time provides precise charge counting
- Example calculation: 0.1 μA beam, 20×20 cm² area
- Dose rate = 1.6×10⁹ atoms/cm²/sec
- Excellent dynamic range (0.01 μA to mA beam currents)
Ion Implanter Design
- Vacuum system with ion source and mass analyzer
- Ion source: ionizes species (e.g., BF₂ gas → B⁺, F⁻, BF₂⁺)
- Extraction voltage (0-30 kV) sets initial ion energy
- E×B filter for mass selection
- Centrifugal force = magnetic force (mv²/r = qvB)
- Only desired mass passes through resolving slit
- High voltage accelerator (50-200 kV) for final energy
- X-Y scan plates for beam rastering across wafer
- Current integrator for dose monitoring
Ion Distribution Physics
- Random collision process with silicon atoms
- Two energy loss mechanisms:
- Nuclear collisions (billiard ball-like)
- Electronic drag forces
- Key parameters:
- Total range: sum of all path segments
- Projected range (Rp): depth projection (more important)
- Statistical process creates distribution of final positions
Profile Characteristics by Ion Mass
- Light ions (Boron): travel deeper, broader distributions
- At 200 keV: Rp ≈ 0.55 μm, very broad profile
- Heavy ions (Antimony): shallow, narrow distributions
- At 200 keV: much shallower than Boron, tight distribution
- Intermediate ions (Phosphorus, Arsenic): between extremes
Gaussian Approximation
- First-order model: N(x) = Npeak × exp[-(x-Rp)²/(2ΔRp²)]
- Two parameters: Rp (projected range), ΔRp (standard deviation)
- Integrated dose Q = √(2π) × ΔRp × Npeak
- Works well for heavy ions, less accurate for light ions
- Tabulated values available in textbooks and literature
Lateral Distribution and Masking
- 3D ion distribution: elongated ellipse in beam direction
- Lateral straggle: ΔRp⊥ (perpendicular to beam)
- Point response function approach for modeling
- Mask edge effects critical for device dimensions
- Lateral straggle under gate determines channel length
- Important for short channel effects
Masking Calculations
- Mask thickness requirement: Xm = Rp* + M×ΔRp*
- * denotes parameters in mask material
- M typically ~5 standard deviations
- Penetrating dose: complementary error function
- Tilted implants create shadowing effects
- Often require symmetric tilts for device uniformity
Profile Evolution During Annealing
- Simple case: Gaussian preserved during diffusion
- Final standard deviation: √(ΔRp² + 4Dt)
- Peak concentration decreases as profile broadens
- More complex behavior in real systems due to TED
Advanced Profile Modeling
- Real profiles show skewness (non-Gaussian behavior)
- Light ions: skewed toward surface (backscattering)
- Heavy ions: skewed deeper (forward momentum)
Pearson IV Distribution
- Four-moment description: Rp, ΔRp, skewness (γ), kurtosis (β)
- Differential equation solution for accurate profiles
- Peak location: Rp + a (offset from Rp)
- Skewness effects:
- γ < 0 (Boron): peak deeper than Rp
- γ > 0 (heavy ions): peak shallower than Rp
- Tabulated parameters available for common dopants
Ion Channeling Effects
- Single crystal silicon has open channels along crystal axes
- Ions can travel much deeper via channeling
- Critical angle (ψc): maximum misalignment for channeling
- Boron <111>: ~3°, Arsenic <111>: ~4.4°
- Dose-dependent effects:
- Low dose: maintains crystal structure, deep channeling tails
- High dose: amorphizes crystal, eliminates channeling
Channeling Control Methods
- Controlled misalignment: 7° tilt + rotation
- Amorphous overlayers (limited effectiveness)
- Residual channeling still occurs at end-of-range
- Critical angle increases as ions slow down
- Creates exponential tail in profiles
Modeling Complexity Hierarchy
- Gaussian (2 parameters): basic approximation
- Pearson IV (4 parameters): accurate for amorphous
- Pearson IV + exponential tail (6 parameters): includes channeling
- Dual Pearson (9 parameters): complex channeling cases
- Monte Carlo: most accurate but computationally intensive
- Boltzmann Transport Equation (BTE): compromise approach
Monte Carlo Simulation
- Follow individual ion trajectories from surface to rest
- Statistical accuracy: error ∝ 1/√N
- Requires ~10⁵ ions for 10% accuracy over 3 decades
- Computationally expensive (hours to days)
- Most accurate for complex geometries and channeling
Key Process Parameters
- Beam energy: determines Rp and profile shape
- Dose: total atoms implanted per unit area
- Tilt angle: controls channeling
- Rotation: randomizes crystal orientation
- Masking materials: defines implant regions
- Wafer temperature: affects damage accumulation
- Dose rate: influences heating and damage kinetics