Electric Grid Fundamentals
- Electric grids = largest machines in existence, stretch across continents
- Zero slack system unlike water systems
- No storage reservoirs or extra supply in pipes
- Electricity consumed moments after production
- Supply must instantly match demand
Electricity Demand Patterns
- Annual peaks: January (winter heating), July (summer AC - highest overall)
- Month-to-month variation <1/3 difference between highest/lowest
- Daily patterns vary by season:
- January: 2-peak trend (7am wake-up spike, evening return-from-work spike)
- July: late afternoon/early evening peak
- Regional variations:
- Southwest: 4pm peak (hottest hour, max AC load)
- Northwest (including Colorado): 6pm peak (post-work appliances, fewer AC units)
- Special events affect demand (Super Bowl Sunday = demand plummet for few hours)
Power Generation Layers
Base Load (Nuclear)
- Run nearly continuously 24/7 except planned maintenance
- Cannot turn off/on easily (full day to shut down/restart)
- Massively expensive construction = economically inefficient to run idle
- Colorado: no nuclear plants currently
Coal Power
- Colorado: 6 coal plants, 42% of state's power supply
- Cannot fire up quickly, take time to reach temperature
- Run essentially continuously like nuclear
- Combined with nuclear = base load (minimum power needed)
Natural Gas Peaker Plants
- Colorado: 25 plants total, 13 simple cycle combustion turbines
- Simple cycle: fastest startup (15 minutes to full power)
- More advanced plants recover hot exhaust but slower startup
- Handle short demand peaks, variable cost due to fuel
Renewable Energy Integration
- Wind/solar power essentially free once installed (no variable fuel costs)
- Creates new uncontrollably variable bottom layer
- Sunny/windy day = excess electricity
- Cloudy/windless day = full peaker plant operation
- Solar/onshore wind = cheapest electricity sources
- Cannot match supply to demand like traditional sources
Energy Storage Challenges
Battery Storage Economics
- Average US household: 30 kWh/day
- Lithium-ion batteries: $130/kWh
- One-day household storage: $3,900 in batteries (excluding infrastructure)
- Average household pays <$1,950/year electricity bills
- Grid-wide installation economically impractical currently
Colorado Battery Systems
- 4 battery storage systems, relatively minor scale
- Fort Carson (largest): 8.5 MW capacity
- Charge at night (low rates), discharge during day
- 13-year payback period
- Expected $500,000 savings over lifespan
Vehicle-to-Grid Potential
- EV forecasts: 1/3 new US car sales electric by 2030
- Rivian R1T example: 135 kWh battery = 4.5 days average household power
- EVs could charge at night/during renewable peaks, supply grid during day
- Vehicle owners compensated by utilities
- Real-world economics unproven (battery degradation concerns)
Hydroelectric Power & Pumped Storage
- Hydro = best of both worlds: green + reliable
- Near-zero carbon impact like wind/solar
- Can start/stop in minutes (minimum flow typically maintained)
- Colorado: 20-year drought limits water availability
- Cabin Creek generating station: pumped storage facility
- Cheap electricity (night/renewable peaks) → pump water to upper reservoir
- Expensive electricity (afternoon demand) → flow through turbines
- Price arbitrage smoothing wind/solar peaks/valleys
Power Transmission Systems
Voltage & Efficiency
- 42% Colorado power from 6 coal sites = centralized generation
- Higher voltage = less transmission loss
- Voltage doubling = quarters power loss
- AC power standard due to easy voltage transformation via transformers
Transmission Line Specifications
- Craig generating station → Rifle: 345 kV, 75 miles, 3.2% loss
- Highest US standard: 765 kV lines
- 6x capacity vs 345 kV
- 0.6% loss per 100 miles
- Theoretical NY→LA transmission: 87% power retention
- Construction costs:
- 345 kV substation: $10.7M
- 230 kV substation: $7.6M
- 345 kV line: $4.5M/mile
- 230 kV line: $2.8M/mile
DC vs AC Transmission
- DC transmission: 0.45% loss per 100 miles (vs 0.6% AC minimum)
- DC challenges: expensive voltage transformation, must convert to AC for grid use
- Pacific DC Intertie example (Oregon→LA):
- Summer: northwest excess → LA AC power
- Winter: LA excess → northwest heating
- Long-distance transmission enables seasonal balancing, renewable integration
Local Distribution Example
- Craig power station → Rifle (345 kV) → step down to 230 kV
- 30 miles east → 69 kV → circle back to Glenwood Springs
- Final steps: 12.47 kV → 120/240/480V (building voltages)
- Glenwood Springs public library final destination