AI summary by TwinMind
How MRI Scanners are Made | How It's Made | Science Channel
Science Channel
9m 42s
MRI Scanner History and Basic Function
- MRI scanner invented 1977, revolutionized medical diagnostics
- Magnetic Resonance Imaging provides inside look at human body without surgery/x-rays
- Uses magnetic fields and radio wave pulses to create images
- Magnet 30,000x stronger than Earth's magnetic field
Magnet Construction and Assembly
- Aluminum casing welded around magnet creating tunnel for patient
- Seams must be extremely tight to contain super cold liquid helium
- Magnet capped and transferred to test chamber after welding complete
- Helium gas pumped into tube, vacuum system removes air
- Sensor confirms no leaks, welds are tight
Insulation and Containment Systems
- Second aluminum tube constructed around magnet as shield
- Aluminized mylar blanket wrapped around magnet
- Originally developed as insulating material for space suits
- Deflects heat to keep magnet cold
- Magnet inserted into steel shell (vacuum vessel)
- Air pulled from space between magnet and vessel creating vacuum insulation
- Exterior spray painted white to protect steel from rust
Cooling System Installation
- Cold head refrigeration unit installed
- Maintains helium at -269°C around primary magnet
- Keeps helium in liquid state
- Without cold head, significant amounts would vaporize and be lost
- Liquid helium pumped into magnet (one of coldest things on planet)
- Fill nozzles turn frosty from extreme cold
- Magnet loses electrical resistance, becomes superconductor generating intense magnetic fields
Gradient Coil Construction
- Controls image orientation with electrical pulses
- Starts with fiberglass epoxy tube cut to correct length
- Worker carves grooves in tube, fills with epoxy
- Copper wire wound into epoxy-filled grooves, adheres forming gradient coil
- Entire tube covered with epoxy to seal wire, prevent vibration during operation
- Etched copper plates layered onto epoxy
- Coil wrapped tightly with Teflon cloth
- Epoxy resin poured onto fabric
- Cooling lines (tubing) wound around gradient coil, adheres to epoxy-coated cloth
- Disperses heat generated by gradient coil
Radio Frequency Coil Assembly
- Second fiberglass tube prepared for RF coil
- Plastic risers and pads attached to fiberglass core
- Risers/pads hold circuitry parts at uniform level
- Adhesive-backed copper strips applied between riser bands
- Copper strips function as antenna - send/receive signals from body, relay to computer for MRI image
- Copper pressed with round tip tool for better adhesion
- Epoxy glue dabbed into riser compartments
- Capacitors inserted into glue-filled compartments
- Store energy and change coil frequency to match requirements
- Capacitor ends soldered to copper antenna
- High voltage inductor boards transferred to pads, screwed in place
- Cable splitter units installed near inductor boards
- Cables routed from splitter to inductors, soldered to inductors
- Plastic cable track placed on RF coil side
- Main power cable snaked through track, soldered to antenna
- Copper antenna stiffened with composite boards to dampen vibrations
- Epoxy applied around all cables to secure and prevent noise
Quality Testing and Final Assembly
- RF coil ends capped with metal domes, bolted tightly
- Highly pressurized air pumped into capped RF coil
- Soapy water sprayed over exterior, checked for air bubbles indicating leaks
- RF coil slides into gradient coil (now has outer fiberglass shell)
- Exterior tubing connected to internal cooling line network
- Coil assembly slides into MRI magnet
- Bracket installed to center coils, maintain small gap from magnet
- Microphones and speakers installed for patient communication
- Emergency signaling system added for patient activation
Final Testing and Completion
- Ultimate test: magnet energized, standard test objects scanned
- Picture clarity confirmed
- Metal and plastic outer casing added
- MRI scanner ready for medical diagnosis