AI summary by TwinMind
Lecture 10: Refractive Index Diagnostics VI: Faraday and Reflectometry
MIT OpenCourseWare
1h 12m 26s
Magnetized Plasma Wave Recap
- Previous lecture covered waves in magnetized plasma
- Geometry: Z-coordinate along static/slowly varying magnetic field B, K vector in Z-Y plane
- Solved determinant of matrix: Ω²s - c²k² identity - diad(k vectors) + iΩε₀ σ tensor = 0
- Two key angles analyzed:
- θ = π/2 (perpendicular propagation): O mode (n² = 1 - Ωp²/Ω²) and X mode (more complex dispersion)
- θ = 0 (parallel propagation): Plus/minus modes with n± = 1 - Ωp²/Ω²/(1 ± Ω_cyc/Ω)
Faraday Effect Theory
- Dispersion relationship valid for wide range of angles where θ < π/2
- Formal criteria: (Ω_cyc/Ω)sec(θ) << 1
- For general angles: use B_parallel = B cos(θ), Ω_eff = eB_parallel/m
- Plus/minus modes have different refractive indices → different phase velocities
- Phase velocity depends on magnetic field sign → enables magnetic field measurement
Polarization Analysis Using Stokes Vectors
- Right-hand circular polarization: S = [1, i]
- Left-hand circular polarization: S = [1, -i]
- Linear X polarization: S = [1, 0] = (R + L)/2
- Linear Y polarization: S = [0, 1] = (R - L)/(2i)
- Arbitrary polarization can be written in either X-Y or R-L basis
Faraday Rotation Measurement
- Small magnetic field approximation: Ω_cyc/Ω << 1 enables linear dispersion
- Phase difference: Δφ_R,L = (Ω/c)∫[1 - Ωp²/Ω² ∓ Ω_cyc/Ω]dz
- X-polarized wave after plasma: X' = (R e^(iφ_R) + L e^(iφ_L))/2
- Results in polarization rotation by angle α
- Rotation angle: α = arctan[(Y·X')/(X·X')]
Faraday Rotation Formula
- Final result: α = (e/2mec)∫(ne/nc)B_parallel dz
- Proportional to λ² (through critical density nc ∝ 1/λ²)
- Line-integrated measurement of B_parallel weighted by electron density
- Requires simultaneous interferometry to measure ∫ne dz for density correction
Practical Implementation
- Differential measurement setup with beam splitter and two polarizers
- Polarizers set at ±β angle from extinction for X polarization
- Intensities: I± = I₀ sin²(α ± β)
- Differential signal cancels unpolarized self-emission background
- α = (1/2)arctan[(I₊ - I₋)/(I₊ + I₋)] × tan(β/2)
- β chosen slightly larger than expected α to avoid phase ambiguity
Measurement Example and Limitations
- Example: ne = 10¹⁹ cm⁻³, B = 1T, λ = 532nm, path = 1cm → α = 3.7°
- Very small rotation angles make measurement challenging
- Requires excellent noise control and stable optical systems
- Cannot distinguish between changes in B and ne without independent density measurement
Reflectometry Theory
- Electromagnetic wave reflects at critical density where n = 0
- Phase shift: Δφ = 2(Ω/c)∫₀^(xc) n(x)dx - π/2
- Not simple radar due to varying wave speed in plasma
- WKB approximation fails near critical density (n → 0)
- Additional π/2 phase shift from reflection process
Multi-frequency Reflectometry
- Measure phase shift vs frequency: dΔφ/dΩ
- Mathematical transformation yields: dΔφ/dΩ = 2∫_(λ)^∞ (xc(λp)dλp)/√(λp² - λ²)
- Abel inversion analogy: λp ↔ r, λ ↔ y
- Inverse gives critical surface location: xc(Ω) = a - (c/π)∫₀^Ω (dΔφ/dΩ')dΩ'/√(Ω² - Ω'²)
Practical Reflectometry Systems
- Historical: Ionospheric measurements using radar technology post-WWII
- Tokamak implementation: Frequency swept 40-80 GHz in ~15 μs
- Heterodyne detection system for phase measurement
- Two-horn system (launcher + receiver) preferred over single horn
- Measures actual density profiles vs line-integrated interferometry
Limitations and Challenges
- Fluctuation measurements extremely difficult due to:
- High sensitivity near critical density
- Contributions from entire plasma path (x < xc)
- 3D scattering effects and wall reflections
- Cannot measure "behind" critical surface (over-the-hill problem)
- Noise amplification in differentiation affects profile accuracy
- Most applications focus on slowly evolving density profiles