Introduction to Magnetic Loss
- Topic: magnetics loss in power electronics components
- Focus: scratch surface of deep topic (full chapter in Principles of Power Electronics Ch. 20)
- Goal: provide basic information for magnetic component design awareness
- Applications: inductor/transformer design for converters
Importance of Magnetic Loss
- Dominant loss source: magnetic components typically main loss source in converters
- Size limitation: loss often determines component size (thermal constraints)
- Two main categories: winding loss and core loss
Basic Winding Loss (DC Analysis)
- DC resistance calculation: R = ρL/A (resistivity × length / area)
- Temperature dependence: copper resistivity increases ~40% per 100°C rise
- Power calculation: P = I²rms × R
- Design trade-off: wire gauge vs. length vs. loss
Current Density Limitations
- Thermal constraints: current density limited by heat transfer
- Scale dependence: smaller components allow higher current densities
- Typical values: ~500 A/cm² for small components, 100-200 A/cm² for larger
- Rule of thumb: start with current density estimate, verify thermal performance
- Chart reference: RM core data showing power density vs. size
Skin Effect
- Mechanism: AC current concentrates at conductor surface due to eddy currents
- Physical cause: changing magnetic flux in conductor generates opposing eddy currents
- Current distribution:
- DC: uniform across wire cross-section
- AC: exponential decay from surface (J ∝ e^(-x/δ))
- Skin depth formula: δ = √(σ/(πμf))
- Decreases as 1/√f
- Determines penetration depth of current
- AC resistance: RAC = RDC × (W/δ) when W >> δ
- Frequency scaling: RAC ∝ √f in high-frequency regime
Skin Effect Demonstration
- Experimental setup: aluminum block as single-turn secondary
- Measurement: magnetic field probe moved across conductor
- Results: 60 Hz vs 240 Hz comparison showed ~2× skin depth difference
- Frequency relationship: 4× frequency change → 2× skin depth change
Litz Wire Solution
- Construction: multiple insulated strands woven/twisted together
- Transposition: each strand spends equal time on surface vs. interior
- Strand sizing: diameter ≈ skin depth for skin effect mitigation
- Applications: high-frequency, high-current designs
Proximity Effect
- Definition: eddy current loss in conductor due to external magnetic fields
- Mechanism: H-field from nearby conductors induces circulating currents
- Transformer example: layered windings create increasing H-field across window
- Field distribution: H-field builds up layer by layer (1H, 2H, 3H units)
- Loss scaling: approximately proportional to square of layer count
- Impact: can increase AC resistance 10-30× over DC value
Proximity Effect Mitigation
- Wire sizing: often requires thinner conductors (≤3 skin depths)
- Counter-intuitive: thinner wire can reduce total loss
- Design challenge: more copper can increase loss due to proximity effect
Core Loss Fundamentals
- Energy calculation: ∮ H·dB per cycle (hysteresis loop area)
- Physical mechanism: work done moving magnetic domains
- Hysteresis loop: B-H relationship shows energy loss per cycle
- Volume scaling: loss proportional to core volume
Core Loss Types
- Hysteresis loss:
- Low frequency: proportional to frequency
- High frequency: frequency dependence varies with material
- Domain movement and associated eddy currents
- Eddy current loss in core:
- AC flux through conductive core material
- Circular currents oppose flux changes
- Significant when core dimensions ≈ skin depth
Eddy Current Mitigation in Cores
- Laminations: thin insulated sheets stacked together
- Sizing: lamination thickness << skin depth
- Applications: 60 Hz transformers, electric machines use laminated steel
- High frequency: ferrites naturally non-conductive, less concern
Empirical Core Loss Modeling
- Formula: Pv = K × f^α × B^β (power per unit volume)
- Parameters: K, α, β determined experimentally
- Data presentation: loss curves vs. flux density at various frequencies
- Design process: look up loss from manufacturer data/curves
- Measurement dependency: very empirical, hard to predict from first principles
Core Loss Demonstration
- Setup: inductor with current (∝H) on x-axis, integrated voltage (∝B) on y-axis
- Results: visible hysteresis loop showing B-H relationship
- Saturation: loop shape changes as core approaches saturation
- Frequency dependence: loop shape varies with frequency