Introduction and Historical Context

  • Discussion of Lyman and Balmer series in hydrogen spectroscopy
    • Balmer series: transitions to n=2 (H-alpha: n=3→2, H-beta: n=4→2)
    • Lyman series: transitions to n=1 (Lyman alpha: n=2→1, etc.)
    • Balmer series discovered first (H-alpha in visible red, others in UV)
    • Lyman series discovered later (all deep UV, harder to detect)
  • Connection to K-shell and L-shell emissions
    • Lyman series ≈ K-shell emission
    • Balmer series ≈ L-shell emission
    • Requires atoms with >3 electrons (lithium-like or heavier)

Natural Broadening

  • Fundamental broadening mechanism - always present, unavoidable
  • Based on finite excited state lifetime (τ)
    • Electrons don't transition instantaneously
    • Random decay process: P(t) ∝ e^(-t/τ)
  • Uncertainty principle relationship: ΔE·Δt ≥ ℏ
    • Energy uncertainty: ΔE ≈ ℏ/(2τ)
  • Calculation of lifetime: 1/τ = 2·Σ(A_ul) where A_ul = spontaneous emission coefficients
  • Fourier transform of exponential decay → Lorentzian line shape
    • I(ν) ∝ I₀/[1 + (ν-ν₀)²(2πτ)²]
    • Full width at half maximum: Δν_half = 1/(πτ)
  • Higher energy lines have shorter lifetimes → broader natural broadening (∝ ν³)
  • Important: Lines are Lorentzian, not Gaussian - affects fitting procedures

Doppler Broadening

  • Due to thermal motion of particles in plasma
  • Non-relativistic limit: Δν/ν₀ = (v/c)
  • Intensity distribution follows Maxwell-Boltzmann velocity distribution
    • I(ν) ∝ exp[-(ν/ν₀ - 1)²mc²/(2T)]
  • Approximately symmetric and Gaussian-like for small shifts
  • Full width at half maximum: Δν_half = 2ν₀√(2T ln(2)/(mc²))
  • Broadening ∝ √(T/m) - proportional to thermal velocity
  • Can measure plasma temperature from line width
  • Heavy ions have less broadening than light ions

Stark Broadening

  • Effect of electric fields from other particles on energy levels
  • Electric field distorts atomic potential → shifts energy levels
  • Linear Stark effect: Δν ∝ E (electric field)
  • Quadratic Stark effect: Δν ∝ E²
  • Electric field scaling: E ∝ 1/r² where r ∝ n^(-1/3) (average particle spacing)
  • Therefore: Δν ∝ n^(2/3) where n = particle density
  • Can measure plasma density from Stark broadening width
  • Also called collisional broadening
  • Dominant in dense, relatively cold plasmas
  • Quantum mechanical calculation required for accurate coefficients

Zeeman Splitting

  • Magnetic field splits energy levels due to coupling with electron magnetic moment
  • ΔE = -μ·B where μ includes orbital and spin angular momentum
  • Example: P-level splits into 3 sublevels (σ⁺, σ⁻, π transitions)
  • Can measure magnetic field strength from splitting magnitude
  • Different transitions have different polarizations
    • Observing perpendicular to B: σ transitions in one polarization, π in another
    • Can determine magnetic field direction from polarization ratios
  • Unresolved splitting appears as broadening when thermal broadening is large
  • Can lead to overestimated temperatures if not accounted for
  • Useful for spatially-resolved magnetic field measurements using different ionization stages

Black Body Absorption Broadening

  • Thermodynamic limit: emission cannot exceed black body spectrum
  • I(ν) ≤ (2hν³/c²)/(e^(hν/kT) - 1)
  • Very bright lines get "capped" by black body limit → flat-topped line profiles
  • Appears as additional broadening when measuring full width at half maximum
  • Only relevant for very intense lines
  • More pronounced at lower temperatures

Applications and Diagnostics

Doppler Shift vs. Broadening

  • Doppler shift: bulk plasma motion (entire fluid velocity)
  • Doppler broadening: thermal spread within moving plasma
  • Heavy impurities (e.g., tungsten) have small thermal broadening
    • Enables accurate Doppler shift measurements for flow velocity
    • Light ions (hydrogen) have large broadening → difficult shift measurements

Active Spectroscopy - Laser Induced Fluorescence (LIF)

  • Pump atoms with laser: L → U transition
  • Observe fluorescence: U → I transition
  • Spatial localization: intersection of laser beam and viewing chord
  • Can measure local atom density if properly calibrated
  • Frequency scanning enables velocity distribution measurement
    • Different laser frequencies excite atoms with different velocities
    • Maps out complete distribution function
  • Requires stable, long-lived plasmas for scanning

Two-Photon Absorption LIF (TALIF)

  • Solution for vacuum UV transitions (e.g., hydrogen Lyman series)
  • Uses two photons at λ/2 wavelength each
  • Virtual intermediate energy level
  • Requires very intense lasers (high probability of simultaneous photon absorption)
  • Enables hydrogen diagnostics without vacuum UV optics
  • Same scanning capabilities as single-photon LIF

TwinMind

Get summaries like this for your own meetings

TwinMind takes notes in the background during meetings, lectures, and calls, then writes the summary for you.

Free plan to get started

No bot joins your calls

Phone, desktop & Chrome apps

Your next meeting, summarized like this

TwinMind listens in the background and turns meetings, lectures, and calls into searchable notes you can chat with. Start free.

Available on phone, desktop & Chrome

Your next meeting, summarized like this

TwinMind listens in the background and turns meetings, lectures, and calls into searchable notes you can chat with. Start free.

Available on phone, desktop & Chrome

Your next meeting, summarized like this

TwinMind listens in the background and turns meetings, lectures, and calls into searchable notes you can chat with. Start free.

Available on phone, desktop & Chrome