AI summary by TwinMind
Lecture 16: Line Broadening
MIT OpenCourseWare
1h 17m 37s
Introduction and Historical Context
- Discussion of Lyman and Balmer series in hydrogen spectroscopy
- Balmer series: transitions to n=2 (H-alpha: n=3→2, H-beta: n=4→2)
- Lyman series: transitions to n=1 (Lyman alpha: n=2→1, etc.)
- Balmer series discovered first (H-alpha in visible red, others in UV)
- Lyman series discovered later (all deep UV, harder to detect)
- Connection to K-shell and L-shell emissions
- Lyman series ≈ K-shell emission
- Balmer series ≈ L-shell emission
- Requires atoms with >3 electrons (lithium-like or heavier)
Natural Broadening
- Fundamental broadening mechanism - always present, unavoidable
- Based on finite excited state lifetime (τ)
- Electrons don't transition instantaneously
- Random decay process: P(t) ∝ e^(-t/τ)
- Uncertainty principle relationship: ΔE·Δt ≥ ℏ
- Energy uncertainty: ΔE ≈ ℏ/(2τ)
- Calculation of lifetime: 1/τ = 2·Σ(A_ul) where A_ul = spontaneous emission coefficients
- Fourier transform of exponential decay → Lorentzian line shape
- I(ν) ∝ I₀/[1 + (ν-ν₀)²(2πτ)²]
- Full width at half maximum: Δν_half = 1/(πτ)
- Higher energy lines have shorter lifetimes → broader natural broadening (∝ ν³)
- Important: Lines are Lorentzian, not Gaussian - affects fitting procedures
Doppler Broadening
- Due to thermal motion of particles in plasma
- Non-relativistic limit: Δν/ν₀ = (v/c)
- Intensity distribution follows Maxwell-Boltzmann velocity distribution
- I(ν) ∝ exp[-(ν/ν₀ - 1)²mc²/(2T)]
- Approximately symmetric and Gaussian-like for small shifts
- Full width at half maximum: Δν_half = 2ν₀√(2T ln(2)/(mc²))
- Broadening ∝ √(T/m) - proportional to thermal velocity
- Can measure plasma temperature from line width
- Heavy ions have less broadening than light ions
Stark Broadening
- Effect of electric fields from other particles on energy levels
- Electric field distorts atomic potential → shifts energy levels
- Linear Stark effect: Δν ∝ E (electric field)
- Quadratic Stark effect: Δν ∝ E²
- Electric field scaling: E ∝ 1/r² where r ∝ n^(-1/3) (average particle spacing)
- Therefore: Δν ∝ n^(2/3) where n = particle density
- Can measure plasma density from Stark broadening width
- Also called collisional broadening
- Dominant in dense, relatively cold plasmas
- Quantum mechanical calculation required for accurate coefficients
Zeeman Splitting
- Magnetic field splits energy levels due to coupling with electron magnetic moment
- ΔE = -μ·B where μ includes orbital and spin angular momentum
- Example: P-level splits into 3 sublevels (σ⁺, σ⁻, π transitions)
- Can measure magnetic field strength from splitting magnitude
- Different transitions have different polarizations
- Observing perpendicular to B: σ transitions in one polarization, π in another
- Can determine magnetic field direction from polarization ratios
- Unresolved splitting appears as broadening when thermal broadening is large
- Can lead to overestimated temperatures if not accounted for
- Useful for spatially-resolved magnetic field measurements using different ionization stages
Black Body Absorption Broadening
- Thermodynamic limit: emission cannot exceed black body spectrum
- I(ν) ≤ (2hν³/c²)/(e^(hν/kT) - 1)
- Very bright lines get "capped" by black body limit → flat-topped line profiles
- Appears as additional broadening when measuring full width at half maximum
- Only relevant for very intense lines
- More pronounced at lower temperatures
Applications and Diagnostics
Doppler Shift vs. Broadening
- Doppler shift: bulk plasma motion (entire fluid velocity)
- Doppler broadening: thermal spread within moving plasma
- Heavy impurities (e.g., tungsten) have small thermal broadening
- Enables accurate Doppler shift measurements for flow velocity
- Light ions (hydrogen) have large broadening → difficult shift measurements
Active Spectroscopy - Laser Induced Fluorescence (LIF)
- Pump atoms with laser: L → U transition
- Observe fluorescence: U → I transition
- Spatial localization: intersection of laser beam and viewing chord
- Can measure local atom density if properly calibrated
- Frequency scanning enables velocity distribution measurement
- Different laser frequencies excite atoms with different velocities
- Maps out complete distribution function
- Requires stable, long-lived plasmas for scanning
Two-Photon Absorption LIF (TALIF)
- Solution for vacuum UV transitions (e.g., hydrogen Lyman series)
- Uses two photons at λ/2 wavelength each
- Virtual intermediate energy level
- Requires very intense lasers (high probability of simultaneous photon absorption)
- Enables hydrogen diagnostics without vacuum UV optics
- Same scanning capabilities as single-photon LIF
