Introduction to Neutral Particle Diagnostics
- Core plasma ions well-confined → need technique to measure distribution function f(V_i) in core
- Existing techniques inadequate:
- Electron cyclotron emission: measures T_e ≠ T_i necessarily
- Laser induced fluorescence: requires electrons in ions (core fully ionized)
- Thompson scattering: measures electron distribution f_e(V) ≠ f_i(V)
- Solution: core ions spontaneously turn into neutrals → escape confinement → detectable outside plasma
Neutral Transport Analysis
- Two key problems: neutral production mechanism + neutral escape probability
- Transport modeled as radiation transport: P(A→B) = exp(-∫α(l)dl)
- Attenuation coefficient α includes three processes:
- Electron impact ionization: σ_e cross-section
- Ion impact ionization: σ_p cross-section
- Charge exchange with ions: σ_c cross-section (resonant, large)
- Velocity ordering: V_i << V_A << V_Te
- Simplified expression: α ≈ (σ_p + σ_c)n_i for energetic neutrals
- Example calculation: 10 keV neutrals, 10^20 m^-3 density → mean free path ~10 cm
- Requirement for detection: line integrated density < 10^19 m^-2 → need "low density" tokamak
Neutral Production Mechanisms
- Edge fueling: neutrals from scrape-off layer penetrate to core via charge exchange
- Probability P_BA calculable from transport analysis
- Creates detectable flux despite low penetration probability
- Radiative recombination: negligible process
- Balance: n_e·n_i·σ_r·v_e = n_e·n_a·σ_e·v_e
- Steady state: n_a/n_i = σ_r·v_r/(σ_e·v_e) ≈ 10^-8 at 1 keV
- Too low for detection
- Neutral beam injection: active method using existing heating/current drive beams
Passive Charge Exchange Spectroscopy
- Measurement setup: plasma → neutrals → stripping cell → magnetic analyzer → detector
- Detector bins measure velocity distribution
- Energy spectrum: log(intensity) vs particle energy shows:
- Maxwellian region: slope = -1/T_i
- Non-Maxwellian tail: fast ions from RF heating, runaways
- Limitation: line-integrated measurement
- Challenge: distinguishing core vs edge neutral contributions (use high-energy cutoff)
Active Neutral Beam Diagnostics
- Neutral beam perpendicular to detector sight line
- Localizes measurement to beam-plasma intersection
- Uses existing heating/current drive beams
- Limited to lower density machines (beam penetration requirement)
Charge Exchange Recombination Spectroscopy (CHERS/CXRS)
- Process: neutral beam + fully stripped impurity A^Z+ → beam ion + A^(Z-1)+* → photon emission
- Makes invisible impurities visible again
- Measurements possible:
- Impurity density from intensity (requires atomic models, absolute calibration)
- Ion temperature T_i from Doppler broadening
- Flow velocity V_flow from Doppler shift
- Localized measurement from beam-detector intersection
- Problems: charge exchange with edge impurities, bremsstrahlung background
- Solution: beam modulation + phase-locked detection
Beam Emission Spectroscopy (BES)
- Collisional excitation of beam neutrals by plasma electrons/ions
- Intensity ∝ n_e (collisional excitation process)
- Measures density fluctuations: I ∝ n_e + Δn_e(t)
- Important for turbulent transport studies
- Complications: must include all relevant atomic processes + beam attenuation
- Can use standard heating beams or specialized diagnostic beams
Motional Stark Effect (MSE)
- Lorentz transformation: beam velocity V_B in magnetic field B creates electric field E = V_B × B in beam frame
- Linear Stark effect: energy shifts Δε ∝ |V_B × B|
- Each energy level splits: Δε = (3nk/2) × (e²/4πε₀a₀Z²) × |E| × R_y
- Quantum numbers: n = 1,2,3...; k = 0,±1,±2,...,±(n-1)
- Transition used: n=3→n=2 (H_α, 656 nm) avoids vacuum UV (Lyman α at 121 nm)
- Selection rules: Δm = 0,±1 → multiple allowed transitions → forest of spectral lines
- Advantages over Zeeman effect: ~10× larger splitting, works with hydrogen
- Polarization analysis: π-polarization ⊥ B, σ-polarization ∥ B
- Application: current profile reconstruction via poloidal magnetic field measurement
- Requires fast, unidirectional beam velocity for large, coherent splitting