AI summary by TwinMind
Lecture 2: Magnetics I
MIT OpenCourseWare
1h 20m 2s
Basic Magnetic Probe Theory (B-dot Probes)
- Simple wire loop with area A in time-varying magnetic field B(t)
- Maxwell's equation: ∇×E = -∂B/∂t
- Voltage output: V = -nAḂ (n = number of loops)
- Called "B-dots" due to Ḃ dependency
- Key assumption: LP/LB << 1 (probe length scale << magnetic field variation scale)
- LP ~ √A (probe characteristic length)
- LB = B/∇B (magnetic field variation scale)
- Signal integration required: B = ∫(V/nA)dt from t=0 to t
Signal Processing Methods
- Passive integration: RC filter (low-pass)
- Active integration: Op-amp with R and C
- Digital integration: Sum V/nA × ΔT
Noise Rejection Techniques
- Differential measurement: Two oppositely-wound loops
- V1 = AḂ + Vcap, V2 = -AḂ + Vcap
- V1 - V2 = 2AḂ (capacitive coupling cancels)
- Capacitive coupling from plasma potential (kV range) to probe
- Probes must be closely spaced for effective cancellation
Alternative Magnetic Field Sensors
- Hall effect sensors/Gauss meters
- J×B force separates charges in semiconductor
- Measures DC/steady-state fields
- Limited by radiation hardening in fusion environments
- Slower response than B-dots
- Faraday rotation sensors
- Polarization rotation: β = VBL (V = Verdet constant)
- Fiber optic implementation possible
- Fast response (limited by digitizer speed)
- Radiation hardening challenges (X-rays cause blanking)
Rogowski Coils
- Helical coil measures enclosed current: V = nAμİ
- Based on Ampère's law: ∮B·dl = μI_enclosed
- Current channel position independent
- Turns per unit length n, area A of individual loops
- Commercial versions available (Pearson coils)
- Only measures İ (time derivative of current)
Plasma Resistivity Measurement in Tokamaks
- Setup: Rogowski coil + voltage loop around plasma
- Energy balance: Ohmic heating = Injected power
- Power balance: VI_ϕ = ∫(J²/σ)dV
- Steady-state assumption: Neglect ∂/∂t(½LI²) term
- Result: σ = (I²/P) × (2R/a²)
- I measured by Rogowski
- P = VI measured by voltage loop
- R, a = tokamak geometry
Temperature Measurement from Conductivity
- Spitzer conductivity: σ = 2×10⁴ T_e^(3/2)/(Z_σ ln Λ) [Ω⁻¹m⁻¹]
- Z_σ ≥ Z (accounts for impurities, similar to Z_eff)
- Coulomb logarithm ln Λ ≈ 10 for tokamaks
- Temperature: T_e ∝ σ^(2/3)
- Measures volume-averaged core temperature (where current flows)
- T^(3/2) dependency amplifies measurement errors
Pressure Measurement via Magnetic Field
- Principle: Pressure balance in MCF devices
- Force balance: J×B - ∇p = 0
- Rewritten form: -∇p + ∇(B²/2μ) + (1/μ)(B·∇)B = 0
- Magnetic pressure + tension force = thermal pressure gradient
- Cylindrical approximation for analysis simplicity
Fourier Decomposition of Magnetic Field
- B_θ(θ) = c₀/2 + Σ[c_m cos(mθ) + s_m sin(mθ)]
- m=0 mode: Axisymmetric (circular)
- m=1 mode: Plasma displacement/shift
- c_m, s_m determine shift direction
- Critical for plasma position control
- Higher modes (m=2,3...) for detailed analysis