Lecture 23: Three-Phase Inverters
MIT OpenCourseWare
51m 12s
Three-Phase Inverter Architectures
- Comparison of three separate single-phase inverters vs three-phase bridge structure
- Three single-phase approach: 12 devices, used for open-ended windings (MIT megawatt system example)
- Standard three-phase bridge: 6 devices, vastly preferred for most applications
- Three-phase bridge advantages: fewer devices, better semiconductor utilization, lower conduction losses
- Exception: very high-frequency applications where switching losses dominate
Three-Phase Bridge Inverter Structure
- Configuration: three bridge legs with MOSFETs/IGBTs and anti-parallel diodes
- DC bus with VDC, reference point at VDC/2 midpoint
- Connection to three-phase loads: Y-connected or Delta-connected
- Neutral typically floating (not connected to reference)
- Eight possible switching states (2³ combinations)
Six-Step Operation
- Direct implementation of diode rectifier pattern in reverse
- Sequential switching: 1-2, 2-3, 3-4, 4-5, 5-6, 6-1 pattern
- Each half-bridge generates square wave, 50% duty cycle
- Line-to-line voltages: six-step waveform, no triple-n harmonics
- Line-to-neutral voltages: triple-n harmonics cancel at neutral
- Generates maximum fundamental component without PWM
- Used in Tesla egg demo example
PWM Control Techniques
- Triangle-intercept PWM implementation
- Triangle carrier wave at switching frequency
- Reference signal: Vref = (Vm/VDC/2) × Vtriangle × sin(ωline×t)
- Comparator generates switching signals Q1(t) and Q4(t)
- Modulation index M = Vm/(VDC/2)
- Linear operation when M ≤ 1
- High switching frequency pushes harmonics away from line frequency
- Superior waveform purity compared to six-step operation
Third Harmonic Injection PWM
- Technique to extend linear range beyond M = 1
- Add M/2 × sin(3ωline×t) to each phase reference
- Extends maximum modulation index to M = 1.15 (15% increase)
- Third harmonic appears only at neutral, cancels in line-to-line voltages
- No distortion in fundamental output despite added harmonics
Modulation Index Limits and Trade-offs
- M ≤ 1: Pure sinusoidal output with PWM
- M = 1.15: Maximum with third harmonic injection
- M > 1.15: Overmodulation with low-frequency harmonic distortion
- M → ∞: Approaches six-step operation (4/π × VDC/2 maximum fundamental)
- Toyota Prius example: accepted overmodulation for higher speed operation
Device Technology Discussion
- Historical preference for IGBTs at high voltage (constant forward drop)
- Modern trend toward wide-bandgap MOSFETs (lower losses)
- Prius inverter example: IGBTs with separate anti-parallel diodes
- Device selection based on minimizing total losses
Voltage Extension Strategies
- Boost converter before inverter to increase VDC
- Dynamic bus voltage control based on operating conditions
- Trade-off between complexity and voltage capability
- Always limited by semiconductor voltage ratings