EMI Testing Setup and Standards

  • EMI testing requires Line Impedance Stabilization Network (LISN) for repeatability
    • LISN contains L_lisn and C_lisn components
    • Connected to 50-ohm spectrum analyzer
    • Eliminates source impedance variability during testing
    • Separate LISN on hot lead and ground lead in most systems
  • Conducted EMI testing typically covers 150 kHz to 30 MHz frequency range
    • Military standards may extend to lower frequencies
    • Test setup details specified by standards
  • Current limits: converter may draw tens of amps, but allowed current back into source limited to tens of microamps

Basic Filter Design Principles

  • Simple capacitor insufficient for EMI compliance
  • Basic LC filter building block: filter capacitor (CF) and filter inductance (LF)
  • Attenuation characteristics:
    • DC: everything passes back (magnitude = 1)
    • Above cutoff frequency (1/√(LF·CF)): rolls off at -40 dB/decade
    • Capacitor impedance falls 10x per decade frequency increase
    • Inductor impedance rises 10x per decade frequency increase
    • Results in 100x attenuation per 10x frequency increase

Component Parasitics Impact

  • Internal parasitics degrade filter performance
  • Filter capacitor parasitics:
    • ESR (R_r) reduces rolloff to -20 dB/decade at high frequencies
    • Parasitic inductance (L_parasitic) creates current divider with LF
    • Performance flattens out instead of continuing rolloff
  • Parasitics sources:
    • Internal component parasitics
    • Layout parasitics (circuit board placement)
    • Parasitic inductance and resistance
    • Parasitic capacitance

Resonance and Damping Issues

  • At cutoff frequency (1/√(LF·CF)):
    • LF and CF appear as open circuit at resonance
    • Current gain (iy/ix) approaches infinity
    • Causes huge circulating currents and instability
  • Output impedance ZX behavior:
    • Low frequencies: ωLF (inductive)
    • High frequencies: 1/(ωCF) (capacitive)
    • At resonance: approaches infinity (open circuit)

Capacitive Damping Strategy

  • Add damping resistor (Rd) in series with damping capacitor (CD)
  • Damping leg provides:
    • Near cutoff: CD acts as short circuit, Rd provides damping
    • At DC: CD acts as open circuit, no DC current loss
  • Design equations:
    • R_out = √(LF/CF) (characteristic impedance)
    • n = CD/CF (capacitor ratio)
    • Rd_opt = R_out × √[(2+n)×(4+3n)/(2n²×(4+n))]
    • ZX_max = R_out × √[(2+n)/n]
  • Typical CD values: 2-10 times CF for adequate damping
  • Component selection considerations:
    • CF: high-frequency performance critical (ceramic/film capacitor)
    • CD: operates near cutoff, can use electrolytic with higher ESR

Inductive Damping Alternative

  • Series combination of LD and RD in parallel with filter
  • Design requirements: LD < LF
  • Near cutoff: LD appears as short circuit, RD provides damping
  • High frequencies: LD becomes inductive, maintains rolloff
  • Advantages: LD is small, carries no DC current
  • Disadvantages: degrades filtering performance slightly above cutoff (-20 dB/decade initially vs -40 dB/decade)

Constant Power Load Effects

  • Power converters act as constant power loads: Pin × VN = Pout
  • Small-signal input resistance: Rvel = -Pout/Iin² (negative resistance)
  • Negative input resistance destabilizes filter
  • Stability condition: net damping resistance must be positive
    • Rnet = (Rd × RL)/(Rd + RL) > 0
    • Requires |Rd| < |RL| for stability
  • Maximum filter output impedance must be well below |Pout/Iin²|

Practical Design Considerations

  • Filter cutoff frequency must be well below switching frequency
  • Converter operates in hundreds of kHz, filter cutoff in kHz range
  • Real-world source impedance affects filter design
  • Filter output impedance ZX appears as source impedance to converter
  • Sufficient conditions for decoupled design:
    1. ZX_max << |negative input resistance| under perfect control
    2. Fixed duty ratio input impedance < filter output impedance across all frequencies

Demonstration Results

  • Live demonstration showed oscillation without damping leg
  • With damping: stable input voltage VN ≈ VS
  • Without damping: severe oscillations in input voltage
  • Emphasizes critical importance of proper filter damping in real systems