AI summary by TwinMind
Lecture 3: Magnetics II
MIT OpenCourseWare
1h 23m 23s
Lecture Recap - B-dot Probes and Rogowski Coils
- B-dot probes: wire loops with area A, sensitive to magnetic field component parallel to loop normal
- Flux through loop: Φ = ∫B·dS, voltage output = dΦ/dt = B·A
- Rogowski coils: B-dots arranged in circle, joined together
- Voltage = (turns per unit length) × (area of loops) × I_dot × μ_R
- Used for current measurement in tokamaks/z-pinches
Plasma Conductivity Measurement
- Power balance: ohmic dissipation = Poynting flux
- ∫(J²/σ) = V × I (steady state assumptions)
- Conductivity formula: σ = I²/(V × geometric terms)
- Geometric terms: 2πR/πa² for tokamak (R = major radius, a = minor radius)
- Conductivity ∝ T_e^(3/2), enables temperature measurement
- Requires two loops: Rogowski coil + voltage loop
Pressure Balance and MHD Equations
- MHD equation: J×B - ∇P = 0 (steady state)
- Focus on cylindrical geometry ("straight tokamak")
- Fourier decomposition: m=0 (diamagnetic term), m=1 (displacement mode)
M=0 Mode - Diamagnetic Measurements
- Integrated MHD equation yields beta_theta parameter
- βθ = 2μ₀<P>/(Bθ(a))²
- Final expression: βθ ≈ 1 + 2[Bφ(a) - <B_φ>]/B_θ(a)²
- Requires three loops: B_θ at edge, B_φ at edge, average B_φ
- Assumptions: B_φ roughly constant, B_φ >> B_θ, β_φ << 1
- Valid for high aspect ratio tokamaks/stellarators at low beta
Diamagnetism vs Paramagnetism
- Diamagnetic: B_φ(edge) > <B_φ> (thermal pressure creates magnetic field dip)
- Paramagnetic: opposite case when β_θ > 1
- Relevant for reversed field pinches, screw pinches
- Diamagnetic drifts flip direction in paramagnetic case
Energy Confinement Time Measurement
- Stored thermal energy: W = (3/2)<P> × volume
- Energy confinement time: τ_E = W/P_input
- P_input = I²R_p for inductively driven tokamak
- Final result: τ_E = (3/8)μ₀<n>T_eπR/R_p
- Total requirement: 5 loops for complete τ_E measurement
- Difficult measurement due to small signal differences (~10% variation)
M=1 Mode - Displacement Measurements
- Measures plasma displacement from geometric center
- B_θ(θ) = (μ₀I/2πa)[1 + (Δ/a)cos(θ)] for displacement Δ in x-direction
- Fourier coefficients: displacement_x = 2a(C₁/C₀), displacement_y = 2a(S₁/C₀)
- Enables real-time feedback control to prevent wall contact
- Sampling theorem considerations for number of probes needed
Toroidal Corrections
- Complex flux surface shifts in toroidal geometry
- Additional terms involving β_θ + L_i/2 - 1 (internal inductance)
- Can determine current profile information (peaked vs hollow)
- Significantly more mathematical complexity
Internal Magnetic Probes
- Direct insertion into plasma with insulation
- Not very perturbative (magnetic fields set by global currents)
- Tri-axial probes measure B_x, B_y, B_z
- Local current measurement: J = (1/μ₀)∇×B
- Noisy due to ΔB/Δx differentiation
- Pressure measurement via J×B force balance (difficult for low beta)
Advanced Techniques with Internal Probes
- Plasma flow velocity via time-of-flight between probes
- Cross-correlation of magnetic field signals
- Supersonic flow creates bow shock around probe
- Shock opening angle: sin(μ) = 1/M (Mach number)
- Sound speed measurement enables electron temperature determination
- Combined technique: V_flow + M + c_s → T_e measurement
- Alternative to complex Thomson scattering diagnostics