Soft Switching Fundamentals Review

  • Soft switching concepts: Zero Voltage Switching (ZVS) and Zero Current Switching (ZCS)
  • Switch transitions: turn-off and turn-on operations
  • Turn-off transition: switch current falls from max to zero in finite time
    • Hard switching: voltage rises then current falls
    • Soft switching: delay voltage rise using capacitor across device
  • ZVS turn-on: make voltage zero before turning switch on
    • Best for high frequency designs
    • Addresses switch capacitance discharge issues
  • ZCS turn-on: delay current rise using series inductor
    • Inductor takes up voltage during turn-on
  • ZCS turn-off: ensure current is zero before turning switch off

Benefits of Soft Switching

  • Reduced switching loss (P_switching decreases)
    • Enable higher switching frequency with smaller components
    • Improve efficiency or combination thereof
  • Reduced EMI through lower dV/dt slopes
    • Smoother waveforms vs sharp square wave transitions
    • Easier filtering requirements

EMI Analysis - Square Wave vs Soft Switching

  • Square wave current/voltage waveforms generate high frequency content
  • Fourier analysis of trapezoidal waveforms:
    • Magnitude: 2ID*sin(nπD)/(πnD) * sin(nπt_rise/T)/(nπt_rise/T)
    • Two sync functions: duty ratio and rise time percentage
  • Square wave (instantaneous transitions):
    • Constant amplitude at low frequencies
    • Falls off as 1/f (20 dB/decade) at high frequencies
  • Trapezoidal wave (finite rise time):
    • Additional 20 dB/decade rolloff at higher frequencies
    • Significantly reduced high frequency content
  • Experimental verification: 100 μs period (10 kHz) waveforms
    • 40 ns rise time → some high frequency reduction
    • 360 ns rise time (3.6%) → significant high frequency reduction
    • 10% rise time → major high frequency content elimination

Device Matching and Implementation Categories

  • Soft switching technique must match semiconductor device characteristics
  • Some devices don't work well with ZVS
  • Circuit implementation depends on:
    • Voltage range requirements
    • Power range requirements
    • Application constraints
  • Two broad implementation categories:
    • Whole circuit designed around soft switching requirements
    • Auxiliary circuits added to standard PWM converters

Resonant Pole Inverter (Category 1 - Integrated Design)

  • DC-AC converter with split DC bus (±VDC/2)
  • Capacitors across each switch for ZVS operation
  • Hysteretic current control operation:
    • Turn on S1, ramp inductor current to +I_peak
    • Turn off S1 (ZVS), voltage rings down, bottom diode conducts
    • Turn on S2 (ZVS), ramp inductor current to -I_peak
    • Turn off S2 (ZVS), voltage rings up, top diode conducts
  • Requirements for proper operation:
    • Minimum positive current needed to ring voltage down
    • Minimum negative current needed to ring voltage up
    • Both currents are functions of capacitor voltage VCF
  • Average output current = average of peak positive and negative currents
  • Characteristics:
    • Variable switching frequency
    • Variable duty ratio
    • High ripple current requirement
    • Very constrained control (can't do harmonic elimination PWM)
    • Compact and efficient design

Auxiliary Resonant Commutated Pole (ARCP) Inverter (Category 2 - Auxiliary Circuit)

  • Standard PWM inverter with auxiliary soft switching circuit
  • Main devices: capacitors across switches for ZVS
  • Auxiliary circuit: resonant inductor LR + bidirectional switch for ZCS
  • Invented early 1990s by Rick Divan at GE (extension of McMurray snubber)
  • Operation principle:
    • Auxiliary circuit operates transiently during main switch transitions
    • Can transition between any main switch states regardless of load current
    • Complex control but maintains PWM flexibility
  • Example transition sequence (bottom diode to top switch):
    • Close auxiliary switch at zero current
    • Current ramps up in resonant inductor
    • Turn on bottom switch at zero voltage
    • Turn off bottom switch, voltage rings with capacitors
    • Top diode conducts, turn on top switch at zero voltage
    • Wait for auxiliary current to return to zero
    • Auxiliary switch opens at zero current
  • Benefits:
    • Reduced switching loss in main devices
    • Reduced dV/dt for lower EMI
    • Maintains full PWM control capability
    • Suitable for motor drives and complex control schemes

Applications and Performance

  • High power motor drives demonstrated
  • Laptop adapter power supplies use resonant converter techniques
  • Next topic: Resonant converters as subset of soft switching converters

TwinMind

Get summaries like this for your own meetings

TwinMind takes notes in the background during meetings, lectures, and calls, then writes the summary for you.

Free plan to get started

No bot joins your calls

Phone, desktop & Chrome apps

Your next meeting, summarized like this

TwinMind listens in the background and turns meetings, lectures, and calls into searchable notes you can chat with. Start free.

Available on phone, desktop & Chrome

Your next meeting, summarized like this

TwinMind listens in the background and turns meetings, lectures, and calls into searchable notes you can chat with. Start free.

Available on phone, desktop & Chrome

Your next meeting, summarized like this

TwinMind listens in the background and turns meetings, lectures, and calls into searchable notes you can chat with. Start free.

Available on phone, desktop & Chrome