Early Photography and X-ray Background
- Early photography only captured shades of gray, squashing entire color spectrum
- Early photographic film mostly sensitive to blue light
- Bright red objects appeared black on camera
- Red light used in darkrooms without ruining photosensitive film
- Film also reacted to X-rays
- X-rays have higher energy, shorter wavelength than visible light
- Pass through objects more easily without scattering
- Translate short wavelengths into visible images
- Ionizing radiation with cancer/radiation poisoning risks
- Fluoroscopes used constant X-ray beams before risks were known
Spectral X-ray Technology Development
- X-rays exist on spectrum from soft to hard X-rays
- Team in Christchurch, New Zealand developing multi-frequency approach
- Take X-rays at several different frequencies
- Translate frequencies to different colors
- Traditional medical imaging doesn't use spectral information
- Airport security uses crude 2-color detection with layered detectors
- New technology captures 8 different colors with extensive computer processing
- Produces 3D images identifying specific materials: bone, water, fat
Technology Origins and Timeline
- Research began in 2002
- Detector design started 10 years earlier
- Technology originated from CERN high-energy physics research
- Developed during Higgs boson research
- Each photon's energy measured individually
- Fast processing required for high photon rates
Technical Specifications
- Pixels: 110 micron square (hair's breadth size)
- Each pixel contains 3,000-4,000 transistors
- Extensive processing for 2D to 3D conversion using computer tomography
- Resolution requires solving tens of billions of equations quickly
- 1 liter volume scan generates ~10 gigabytes of data
Color Assignment and Visualization
- Bone typically assigned white (matches expectations)
- Iodine solution assigned red (clear in reality)
- Color choices based on: visual appeal, informativeness, ease of understanding
Clinical Development Progress
- 2006: First mouse scan
- Currently: Ready for human testing, first clinical trial starting
- Challenges scaling from mouse to human:
- Higher energy X-rays needed for human penetration
- Larger detector areas for reasonable scan times
- Data handling for large volumes
Radiation Dose Comparison
- Current scanner uses ~50% X-rays compared to standard CT
- Wrist imaging dose equivalent to several hours to 1 day background radiation
- Technology operates at very low count rates
- Can measure statistical/quantum noise easily
- Goal: Same dose but 10x more information
Future Applications
- Next 6 months: Broken arms, finger injuries
- 1 year timeline: Blocked arteries, disease detection
- Capability to identify specific materials: calcium, iodine, fat, metal